Sign In | Join Free | My xuijs.com
China SHANGHAI CHONGYANG WATER TREATMENT EQUIPMENT CO.,LTD logo
SHANGHAI CHONGYANG WATER TREATMENT EQUIPMENT CO.,LTD
PROFESSIONAL INNOVATION EXCELLENT SERVICE
Site Member

2 Years

Home > Reverse Osmosis Water Filter System >

Food Industry Reverse Osmosis Water Filter System Drinking Water Treatment Machine

SHANGHAI CHONGYANG WATER TREATMENT EQUIPMENT CO.,LTD
Contact Now

Food Industry Reverse Osmosis Water Filter System Drinking Water Treatment Machine

Brand Name : CHONGYANG

Model Number : CY-RO-10000L/H

Certification : ISO ,CE

Place of Origin : China

MOQ : 1

Price : Negotiation

Payment Terms : L/C, T/T

Supply Ability : 100 Sets/Month

Delivery Time : With 30-40 Days

Packaging Details : According to export standard

Equipment Name : Pure Water Making Machine

Softener : Softening Resin

ACF : Activated Carbon

MMF : Quartz Sand

RO Brand : DOW ,HYDRANAUTICS

Control Method : SEIMENS PLC+HIM

Pump Brand : Grundfos , CNP

Flowmeter : KROHNE

Conductivity : 1-5 μS/cm

Pressure : ≤ 0.3Mpa

Contact Now

Product Name:Food Industry Reverse Osmosis System Packaged Drinking Water Treatment Machine

How can I prevent contamination of purified water in an RO system?

Contamination of purified water in a reverse osmosis (RO) system can occur if the storage tank or delivery system is not properly maintained. Here are some steps you can take to prevent contamination:

Clean the storage tank: Regularly cleaning the storage tank can help prevent the build-up of bacteria and other contaminants that can affect the quality of the purified water. Follow the manufacturer's instructions for cleaning and sanitizing the tank.

Replace filters: Replace the pre-filters, post-filters, and other filter elements according to the manufacturer's recommended schedule. This will help ensure that the water is properly filtered and reduce the risk of contamination.

Use food-grade materials: Use food-grade materials for all components that come into contact with the purified water, such as tubing, fittings, and storage containers. This will help prevent leaching of harmful chemicals and other contaminants into the water.

Use proper hygiene: When handling the RO system or dispensing the purified water, use proper hygiene practices, such as washing your hands and using clean utensils and containers.

Test the water quality: Periodically test the quality of the purified water to ensure that it meets the desired standards. If you detect any abnormalities, such as an off taste or odor, stop using the water and investigate the cause.

Regular maintenance: Regular maintenance, such as cleaning and sanitizing the system, will help prevent the build-up of contaminants and improve the overall quality of the water. Follow the manufacturer's recommended maintenance schedule and procedures.

The Partial Product Specification:

Type

Capacity

(M3/H)

Pipe DN

(mm)

WP

(MPa)

Material Work Method
CY-RO-0.25 0.25 DN20 ≤1.0 Stainless Steel/Carbon Steel Full Auto/Semi Automatic
CY-RO-0.5 0.5 DN20 ≤1.0 Stainless Steel/Carbon Steel Full Auto/Semi Automatic
CY-RO-1 1 DN25 ≤1.0 Stainless Steel/Carbon Steel Full Auto/Semi Automatic
CY-RO-2 2 DN32 ≤1.0 Stainless Steel/Carbon Steel Full Auto/Semi Automatic
CY-RO-3 3 DN40 ≤1.0 Stainless Steel/Carbon Steel Full Auto/Semi Automatic
CY-RO-5 5 DN50 ≤1.0 Stainless Steel/Carbon Steel Full Auto/Semi Automatic
CY-RO-10 10 DN75 ≤1.0 Stainless Steel/Carbon Steel Full Auto/Semi Automatic
CY-RO-20 20 DN100 ≤1.6 Stainless Steel/Carbon Steel Full Auto/Semi Automatic
CY-RO-30 30 DN125 ≤1.6 Stainless Steel/Carbon Steel Full Auto/Semi Automatic
CY-RO-40 40 DN150 ≤1.6 Stainless Steel/Carbon Steel Full Auto/Semi Automatic
CY-RO-50 50 DN200 ≤1.6 Stainless Steel/Carbon Steel Full Auto/Semi Automatic

Food Industry Reverse Osmosis Water Filter System Drinking Water Treatment Machine

Food Industry Reverse Osmosis Water Filter System Drinking Water Treatment Machine

FAQ:

1.Question:How often should I replace the filters in a reverse osmosis system?

Answer:As a general guideline, it's recommended that the pre-filter and post-filter be replaced every 3-6 months.

2.Question:How to maintain the big capacity Reverse Osmosis System ?

Answer: 1.Regularly check the system for leaks 2.Monitor water pressure 3.Inspect and clean the pre-filters.

3.Question: How to install RO Plant?

Answer:Install the RO system equipment, including pre-filters, pumps, membranes, and post-filters, according to the manufacturer's instructions and any applicable regulations,we can provide video by wechat ,whatsapp number on-line .

4.Question: Where is the CHONGYANG Water located ?

Answer: SHANGHAI ,JIANGSU


Product Tags:

Food Industry Reverse Osmosis Water Filter System

      

1μS/cm Reverse Osmosis Water Filter System

      

5μS/cm drinking water treatment machine

      
Best Food Industry Reverse Osmosis Water Filter System Drinking Water Treatment Machine wholesale

Food Industry Reverse Osmosis Water Filter System Drinking Water Treatment Machine Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SHANGHAI CHONGYANG WATER TREATMENT EQUIPMENT CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0